Oil & Gas

SignalFire Telemetry products connect you with crucial product and hardware data at any of your oil and gas operation sites—whether it’s a pump, pipeline, or storage tank.

Water & Wastewater

SignalFire Telemetry devices install anywhere water asset monitoring is needed, whether it’s for collection purposes, treatment, or delivery.

General Industrial

SignalFire Telemetry devices can monitor key assets and can do it affordably, without any renovation or high-priced engineering costs. They install easily with no required cable or additional power. The data is available on your phone or computer and the cloud service can even output to your corporate system to integrate with the rest of your data and keep your operation running.

Agriculture

SignalFire Telemetry devices can monitor and manage water supplies and additives throughout the property, helping you avoid catastrophic shortages and keep your irrigation plan on track.

Tanks & Terminals

Avoid costly product loss in bulk storage tanks, terminals, and transportation movements. Whether calling for tank levels, gauge pressure, or even movement pumps or pipelines, SignalFire products can fill any monitoring gap throughout a facility.

Environmental

Environmental fines for businesses are frustrating and can bring business to a standstill until they’re worked out. No business wants to hurt the environment, and in competitive markets stopping production affects the bottom line and staff. But there are effective and affordable solutions with SignalFire Telemetry devices.

Refining & Petrochemical

Expand visibility and control of your refinery or petrochemical processing facility without expensive renovations or redesigns. And do it with your current gauges and hardware. SignalFire telemetry devices are designed to work in harsh chemical environments and meet the strictest safety and security standards

Utilities

No matter the size of your service map, monitoring remote assets ensures efficiency and keeps your operation in compliance. That’s how SignalFire devices can really help, offering the most affordable and effective monitoring solution that will monitor liquid, gas, electricity, and other assets.

Document Center

Browse all documentation pertaining to SignalFire products.

Cloud Setup

Have a RANGER? Set up your Cloud account here.

Case Studies

Explore the diverse applications of SignalFire Wireless Telemetry Systems across different industries.

Brochures

Access our latest brochures to explore comprehensive information about our products and services.

Commonly Supported Sensors

Easily find the sensors that are compatible with our systems on this dedicated page.

Photos

Explore a comprehensive collection of images showcasing our products, installations, and real-world applications.

News & Articles

Stay up to date with the latest content from SignalFire.

Videos

Explore our video library.

Software Downloads

Get access to the RANGER and SignalFire Toolkit Software.

Contact Tech Support

900MHz RF

AirQ Scout-LCD

The AirQ Scout‑LCD is a modular wireless gas detection platform with integrated 900 MHz wireless communications. It continuously monitors gas concentration at the point of risk and transmits measurements wirelessly to a SignalFire Gateway or RANGER900 for integration into SCADA, DCS, or cloud systems. Suitable for measuring: H2S, CO2, LEL

Technical Specifications

Physical Specifications:

  • Dimensions: 8” x 7” x 4” (20cm x 18cm x 10cm)
  • Weight: 2 Lbs (0.9Kg)
  • Housing Material: Industrial polycarbonate UV rated
  • Enclosure Protection: IP65
  • Mechanical installation: Flange mount

Electrical Specifications:

  • Input Power:
    • Integrated Battery: 72A/h four (4) D cell lithium battery pack. Field replaceable.
    • Solar (optional): Sentinel HC-Solar System , C1D1 with integrated rechargeable battery
  • Battery Life: 24 months: Continuous Gas Sampling, 5-minute reporting to Gateway

Environmental:

  • Ambient Operating Temperature: -40 to +131°F (-40°C to +55°C)
  • Humidity: 0% – 99% non-condensing

Local Interface

  • Transflective Display: High resolution graphic display with backlight (can operate down to 0°F (-20°C)
  • Local Keypad: 5 Button Keypad for local diagnostics, bump tests, and calibration
  • Alert Notification: Bright red LEDs, blink when gas exceeds alarm threshold
  • Clock: Real-Time Clock , stores calibration events. CR2032 coin cell battery included to maintain time.
  • Local Computer Configuration: USB-C port, requires SignalFire Toolkit Software

Communications:

  • Data Transmission: Report interval 5 seconds to 2 hours
    Configurable measurement threshold to report on exception.
  • Data Interface: Requires a SignalFire Gateway. Gateways support Modbus RTU, Modbus-TCP, EtherNet/IP, MQTT/Sparkplug
  • RF Radio Power: 40mW, Receive Sensitivity -109dB
  • RF Distance: 0.5 mile (800 meters)
  • RF Band: 902–928 MHz, FHSS, license-free ISM Band
  • Antenna: Internal omni-directional Antenna
  • Cloud Connectivity / Monitoring: SignalFire Cloud connectivity via RANGER900 or PATRIoT Gateway

Gas Sensor:

  • H2S
    • Technology: Electrochemical
    • Detection Method: Diffusion
    • Sensitivity: 0-100ppm (1ppm MDL)
    • Accuracy: +/- 2% of full scale
    • Zero Baseline Shift: <1% of full scale
    • Span Drift: <2% signal loss per year
    • Temperature Range: -40°F to 131°F (-40°C to +55°C)
    • Humidity: 15% to 95% non condensing
    • Pressure Range: 1 atmosphere +/- 0.1 atm
  • CO2 Pending
  • LEL Pending

Gas Sensor Diagnostics

  • Sensor Life: Gas sensor reports remaining life in increments of 25%
  • Sensor Data: Sensor Calibration data and date stored in sensor module
  • Sensor Fault Reporting: Missing Sensor, VDC Fault, Over Range, Under Range

Approvals:

  • Hazardous locations (pending): Class 1 Division 1
    Certified, Groups C & D. Temperature Code T4
    Certified to CSA C22.2 No. 213:2017, Conforms to UL 121201:2017
  • ISM Band: Compliant with FCC Part 15, IC (Industry Canada)
  • FCC ID: Pending
  • IC ID: Pending

Accessories:

  • 4DPAK battery: 72A/h battery pack with super capacitor
  • Sentinel HC-Solar System: High Capacity Intrinsically Safe Solar System, 9.0AH Capacity

Features

01
Integrated smart gas sensor with internal diagnostics and stored calibration data

02
Local LCD with visual indication of gas level, sensor status, and remaining sensor life
03
Integrated keypad for zero and span calibration, bump testing, and alarm checks – no laptop or handheld required
04
900 MHz license‑free ISM band radio with 0.5 mile (800 m) line‑of‑sight range
05
Continuous or scheduled (emissions) measurement modes with fast sensor sampling

06
Reports gas concentration plus sensor health and fault conditions to the supervisory system
07
Long‑life 72 A/h Class I Division 1 battery pack, field replaceable
08
IP65 industrial polycarbonate housing with integrated, protected antenna
09
Class I Division 1 certified (pending), Groups C, D, T4 (hazardous locations)

Intrinsically Safe Gas Monitor with Wireless Telemetry

The AirQ Scout‑LCD is a modular wireless gas detection platform with integrated 900 MHz wireless communications. It continuously monitors gas concentration at the point of risk and transmits measurements wirelessly to a SignalFire Gateway or RANGER900 for integration into SCADA, DCS, or cloud systems.

The smart gas sensor is powered from the built‑in 72 A/h battery pack and uses embedded signal processing to deliver stable, accurate readings with long‑term stability and predictive diagnostics. It automatically compensates for temperature, communicates digitally with the transmitter, and stores calibration data and sensor life information internally to minimize field
setup and maintenance errors.

A local LCD display, alarm indicators, and sealed keypad enable full field operation – including zero/span calibration, bump tests, and alarm checks – without laptops, handheld programmers, or special magnetic tools, allowing fast service in Class I Division 1 environments. In addition, two bright red LED lights provide for local alarm notification whenever the gas exceeds a threshold.

TitleCategoriesFile TypeLinkhf:doc_categorieshf:doc_tagshf:tax:language
AirQ Scout-LCD DatasheetDatasheetpdfdatasheet900-mhz airq-scout-lcden
AirQ Scout-LCD Dimensional DrawingDrawingpdfdrawing900-mhz airq-scout-lcden
AirQ Scout-LCD ManualManualpdfmanual900-mhz airq-scout-lcden

Sensor Specifications

Gas Sensor Specifications Details
H2S Technology: Electrochemical
Detection Method: Diffusion
Sensitivity: 0-100ppm (1ppm MDL)
Accuracy: +/- 2% of full scale
Zero Baseline Shift: <1% of full scale
Span Drift: <2% signal loss per year
Temperature Range: -40°F to 131°F (-40°C to +55°C)
Humidity: 15% to 95% non condensing
Pressure Range: 1 atmosphere +/- 0.1 atm

Measurement Modes

Sensor Measurement Mode Sensor Power & Measurement Frequency Values Reported
H2S Continous Sensor continuously powered.
Values reported every 5 min (configurable) or by exception.
PPM
Atmospheric Pressure
Ambient Temperature
Relative Humidity
Absolute Humidity