Oil & Gas

SignalFire Telemetry products connect you with crucial product and hardware data at any of your oil and gas operation sites—whether it’s a pump, pipeline, or storage tank.

Water & Wastewater

SignalFire Telemetry devices install anywhere water asset monitoring is needed, whether it’s for collection purposes, treatment, or delivery.

General Industrial

SignalFire Telemetry devices can monitor key assets and can do it affordably, without any renovation or high-priced engineering costs. They install easily with no required cable or additional power. The data is available on your phone or computer and the cloud service can even output to your corporate system to integrate with the rest of your data and keep your operation running.

Agriculture

SignalFire Telemetry devices can monitor and manage water supplies and additives throughout the property, helping you avoid catastrophic shortages and keep your irrigation plan on track.

Tanks & Terminals

Avoid costly product loss in bulk storage tanks, terminals, and transportation movements. Whether calling for tank levels, gauge pressure, or even movement pumps or pipelines, SignalFire products can fill any monitoring gap throughout a facility.

Environmental

Environmental fines for businesses are frustrating and can bring business to a standstill until they’re worked out. No business wants to hurt the environment, and in competitive markets stopping production affects the bottom line and staff. But there are effective and affordable solutions with SignalFire Telemetry devices.

Refining & Petrochemical

Expand visibility and control of your refinery or petrochemical processing facility without expensive renovations or redesigns. And do it with your current gauges and hardware. SignalFire telemetry devices are designed to work in harsh chemical environments and meet the strictest safety and security standards

Utilities

No matter the size of your service map, monitoring remote assets ensures efficiency and keeps your operation in compliance. That’s how SignalFire devices can really help, offering the most affordable and effective monitoring solution that will monitor liquid, gas, electricity, and other assets.

Document Center

Browse all documentation pertaining to SignalFire products.

Cloud Setup

Have a RANGER? Set up your Cloud account here.

Case Studies

Explore the diverse applications of SignalFire Wireless Telemetry Systems across different industries.

Brochures

Access our latest brochures to explore comprehensive information about our products and services.

Commonly Supported Sensors

Easily find the sensors that are compatible with our systems on this dedicated page.

Photos

Explore a comprehensive collection of images showcasing our products, installations, and real-world applications.

News & Articles

Stay up to date with the latest content from SignalFire.

Videos

Explore our video library.

Software Downloads

Get access to the RANGER and SignalFire Toolkit Software.

Contact Tech Support

900MHz RF

AirQ Scout

The AIRQ Scout is a modular, wireless gas detection device featuring integrated 900MHz RF communication for transmitting gas measurements to a SignalFire Gateway or RANGER900. Ideal for methane emissions monitoring. Data is relayed to supervisory systems via Modbus or to the SignalFire Cloud through LTE-M CAT M1 / NB-IoT when using the RANGER900. Powered by a built-in 72Ah battery, it employs advanced smart gas sensor technology for low power consumption, high accuracy, and long-term stability with minimal calibration. The sensor also compensates for temperature and humidity to ensure reliable, low-drift measurements and extended battery life.

Technical Specifications

Physical Specifications:

  • Dimensions: 7.5″ x3″ (19cm x 7.62cm) – Without L shaped bracket
  • Weight: 2 Lbs (0.9Kg)
  • Housing Material: Industrial polycarbonate UV rated
  • Enclosure Protection: IP67
  • Mechanical installation: L-Shape bracket with u-bolt

Electrical Specifications:

  • Input Power: 72Ah four (4) D cell lithium battery pack. Field replaceable.
  • Battery Life: 15 months in Continuous Sampling Mode. 44 months in Emissions Mode (Sampling @ 15 min).
    48 months in Emissions Mode (Sampling @ 30 min)
  • Local Configuration: 4-Pin serial configuration port. Requires SignalFire USB-4pin cable

Environmental:

  • Ambient Operating Temperature: -40 to +167°F (-40°C to 75°C)
  • Humidity: 0% – 99% non-condensing

Communications:

  • Data Transmission: Report interval 5 seconds to 2 hours.
    Configurable measurement threshold to report on exception.
    Configurable sampling as fast as every 5 seconds.
  • Data Interface: Requires SignalFire’s Gateway. Output of Gateway supports Modbus RTU, TCP, Ethernet/ IP (Pending), MQTT/
    Sparkplug (Pending)
  • RF Radio Power: 40mW
  • RF Distance: 0.5 mile (800 meters)
  • RF Band: 902–928 MHz, FHSS, license-free ISM Band
  • Antenna: Internal Omni-directional Antenna

Gas Sensor:

  • CH4 Methane
    • Detection Range: 50 – 1,000,000 PPM
    • Resolution: 1 PPM
    • Accuracy: +/- 10% > 300PPM
    • Measurements: PPM, Temperature, Atmospheric Pressure, Absolute Humidity, Relative Humidity

Approvals:

  • Hazardous locations (pending): Class 1 Division 1
    Certified, Groups C, D. Temperature Code T4
    Certified to CSA C22.2 No. 213:2017, Conforms to UL 121201:2017
  • ISM Band: Compliant with FCC Part 15, IC (Industry Canada)

Accessories:

  • USB-4 Pin Cable: USB cable with 4 pin adaptor. 3 feet long (1 meter)
  • 4DPAK battery: 72Ah battery pack with integrated fuse and super capacitor
  • Anti-Theft Locking Ring: Aluminum ring with security screws and bottom plate to lock cover on device
  • L-Shape bracket with U-Bolt (included
    when purchasing AirQ Scout):
    Aluminum L-Shape bracket with U-bolt and mounting holes to install AirQ Scout

Features

01
Integrated gas sensor (See table below)

02
Integrated and protected antenna
03
Continuous measurement or Scheduled
04
Fast sensor sampling
05
Reports sensor specific measurements (See table below)

06
Measurements include: PPM, LEL, Ambient Temperature, Relative Humidity, Absolute Humidity

Revolutionizing Greenhouse Gas Monitoring

The AIRQ Scout is a modular wireless gas detection platform with integrated RF 900MHz wireless communications. Ideal for methane emissions monitoring.

It monitors the presence of a gas and transmits the measurement wirelessly to a SignalFire Gateway or a RANGER900. The measurements are integrated in a supervisory system using Modbus communication at the gateway. When using the RANGER900, the measurement are transmitted to the SignalFire Cloud using LTE-M CAT M1 / NB-IoT cellular connectivity.

The smart gas sensor is powered from the built-in 72Ah battery. It uses the latest in smart gas sensor technology providing for low power demand, stable and accurate measurement as well as long term stability with little to no calibration required. It automatically compensates for temperature and humidity when sampling a measurement and therefore delivers accurate
measurements with low drift. It’s low power requirements allow for long battery life.

TitleCategoriesFile TypeLinkhf:doc_categorieshf:doc_tagshf:tax:language
AirQ Scout DatasheetDatasheetpdfdatasheet900-mhz airq-scouten
AirQ Scout ManualManualpdfmanual900-mhz airq-scouten

Sensor Specifications

Gas Sensor Specifications Details
CH4
METHANE
Technology: MEMS Transducer
Detection Range: 50 – 1,000,000 PPM
2 SCFH @ 30′ (10m) distance
Resolution: 1PPM
Calibration: Factory Calibrated
Accuracy +/-10% > 300PPM (typical @ 20DecC / 50% RH)
Temperature -40DegC to +75DegC
Atmospheric: 80kPa – 120 kPa
Measurements Provided: PPM, Temperature, Atmospheric Pressure, Absolute Humidity, Relative Humidity
Damp Heat-Steady State: 500 hours @ 40°C/93% RH
Temperature Cycling: From -40°C to 85°C for 200 cycles
Sand/Dust: Sand: 150-850 µm SiO2 particle size, 23 m/s nom. velocity, 1.5 hrs @70°C per axis, 3 axes

Dust: Red China Clay, 1.5 m/s nom. velocity, 6 hrs @ 20°C and 6 hrs @ 70°C
Key Features Built-in environmental compensation – Inherently poison resistant – No calibration required – Supports 15+ year lifetimes
H25
Hydrogen Sulfide
Future Future
Refrigerants Future Future
Hydrogen Future Future
Flammables Future Future

Measurement Modes

Sensor Measurement Mode Sensor Power & Measurement Frequency Values Reported
CH4 Continous Sensor continuously powered. Values reported every 5 min or by exception. PPM, Atmospheric Pressure, Ambient Temperature, Relative Humidity, Absolute Humidity
Emissions Sensor powered for 5 minutes at a set report interval. Values reported at the end of the 5 min sensor measurement time. PPM, Atmospheric Pressure, Ambient Temperature, Relative Humidity, Absolute Humidity