Do I need a pull up or pull down resistor on the RANGER for my pulse output meter?
August 9, 2021The RANGER has an internal 470k pull-up resistor to 3.3V and typically does not require any external resistors when...
-
Can I add an expansion card to the Pressure RANGER?
August 9, 2021No, the Pressure RANGER only supports its built-in pressure sensor. For applications that need measurement points in addition to...
-
How many days can a Solar Panel power a RANGER without sunlight?
August 9, 2021This depends on the connected sensor(s), sensor-on time and reporting interval. The RANGER ToolKit will provide the average current...
-
-
Does the digital input still count pulses in between reporting interval?
August 9, 2021The digital inputs continually count and totalize input pulses between reports
-
What is the minimum sensor on time?
August 9, 2021The Sensor On Time can be set to 0 for externally powered sensors, and as low as 0.001 seconds...
-
When should I use an external antenna ?
August 9, 2021An external antenna can be useful in applications whenever the signal is -110dbm or less or when the connection...
-
Can the RANGER do flow totals?
August 9, 2021Any of the RANGER’S digital inputs can be configured for flow mode using the RANGER ToolKit or the SignalFire...
-
What is the relay rated for?
August 9, 2021The relay is a latching type and is rated 2A @ 30VDC; 0.3A @ 110VAC; 0.5A @ 125VAC
-
How do I calibrate the analog input?
August 9, 2021Connect the RANGER ToolKit to the RANGER. Click on I/O tab Set the attached transmitter (or other mA source)...